Due to the complexity and inherent importance of a system covering a life protection risk, training on. The twinflex manual call point mcp allows for user activation of the fire alarm system. The control panel will then carry out a number of checks over a specified period of time to confirm the detector is still in alarm and is a genuine fire. The twinflex multipoint detector head is a 2wire device which is used with both twinflex and twinflex pro systems. For example, the application allows up to 12way calling for free, but users must pay per caller above that number.
The panel can also differentiate between a manual call point and a detector alarm. This manual is intended as a guide to the engineering and commissioning principles of the twinflexpro 2wire fire detection and alarm system and covers the system hardware information only. All models of the detector are designed specifically to be used with the fike twinfl. The twinflex control panel provides a general alarm operation in response to a fire activation, i. Buy this fike fike 2040001 twinflex multipoint asd detector with sounder. The twinflexpro two wire fire alarm system incorporating the multipoint asd combined smoke and heat detector with optional builtin sounder and strobe, allows the whole system to be easily installed using only one pair of wires per zone. Twinflex fire alarm installation manual blue every day. Using an optical smoke sensing chamber and a thermistor, the multipoint asd detector can be easily configured to detect smoke, heat or a combination of both. Unlike most conventional fire alarm systems, which require separate pairs of cables for detector zones and sounder circuits, the twinflexpro.
The fike 604 0004 4 zone contractor kit includes the following equipment. Fike twinflex fire trade supplies fire alarm system. Fike twinflex pro 2, 4 or 8 zone fire alarm kit discount. This manual is intended as a guide to the engineering and commissioning principles of the twinflexpro. Buy fike twinflex pro fire alarm control panels, sounders, detectors and spares from stock at low trade prices, with quick shipping at. Rafiki twinflex fire alarm systems twinflex fire alarms. Twinflex pro repeater panel engineering and commissioning manual fire alarm controls the main fire alarm controls may be enabled by turning the key switch to the controls enabled position to go from access level 1 to access level 2. These devices can be adjusted to operate as either a smoke detector or heat detector simply by flicking a switch on the device itself. At the end of this checking period, if the detector ceases to signal alarm, the control panel will automatically reset the detector sounder and the system will revert to its normal state. Each kit contains a 2, 4 or 8 zone twinflex pro panel, 7 twinflex multipoint detectors with sounder, 2 twinflex manual call points and a head removal tool. Twinflex multipoint 2020003 security sensors pdf manual download. The rafiki twinflex multipoint asd detector is designed for use as part of a twinflex two wire fire alarm panel system. Fike twinflex 2 zone fire alarm kit, fire protection panels. The installation must also meet the requirements of any local authority.
Twinflex is the name of the range of control panels and associated devices which together form the fire alarm system installed in the premises, and is derived from the method of wiring whereby trigger devices detectors and call points are connected to the same pair of wires as sounders, unlike the majority of. The twinflex panel is able to recognise and separately indicate a detector alarm and a manual call point alarm. Fike twinflex fire alarm systems are now available from discount fire supplies. The rafiki twinflex is a two wire fire alarm system. The twinflex fire alarm kits include most of the components required for a full fire alarm system. Fike 402 0007 twinflex weatherproof manual call point. This manual is intended as a guide to the engineering and commissioning principles of the. Smoke, heat, and multisensor 2040001 online from sparks direct at our low price of. Fike classes the twinflex pro range as analogue nonaddressable. The twinflexpro2 is able to recognise and separately identify between smoke detector, heat detector and a manual call point alarm. Repeater panel engineering and commissioning manual to be retained by the commissioning engineer. Fike twinflex multipoint asd detector with sounder 2040001. Rafiki twinflex manual call point 402 0002 for two wire fire.
Fikes multipoint detector product line has broken new barriers in fire detection and alarm. Theres nothing more important than building safety, and fire alarm specialists flex have proven a name to trust time and time again in creating the systems any building needs to help people leave safely in the event of emergency as well as activating the fire alarm. Twinflex fire alarm systems are installed using only one pair of wires and two types of devices twinflex multipoint detectors with optional sounder and twinflex manual callpoints. This system includes the multipoint detector which is available with or without a sounder. Once operated the device latches into the alarm position and requires manually resetting via a special key.
Introducing rafiki twinflex, conventional fire alarm systems. This guide is provided to enable the person responsible for the fire alarm system see. An optional clear front cover is available if required part no. The detectors and callpoints are arranged in zones to enable the location of a fire alarm to be. This is due to the architecture which is used within the design of the panel. The detector part of the unit can also be configured to detect either smoke ro heat sources.
Twinflex v3 control panel engineering and commissioning instructions. Every device has an inbuilt end of line signal, which may be activated as required. Both detectors and manual call points have a built in eol switch so that any device may be set as the end of line monitor. Jun 23, 2016 twinflex fire alarm installation manual for mac performs well and is easy to set up and use.
Including rafiki twinflex panels, detectors, call points and sounders. Simple to install and can be set as flush or surface mount, with a resettable element and eol end of line set via a switch within. The detector must be installed in compliance with the control panel installation. This time, we have the pleasure to collaborate with one of our main manufac. View and download fike 2040003 twinflex multipoint asd installation and maintenance instructions online. Introducing rafiki twinflex, conventional fire alarm. If extra sound is required, or for areas that do not require. The device is available with or without an integral sounder, but is.
Fike twinflex 2 zone fire alarm kit white quick specifications. Discuss twinflex fire alarm zone fault comes and goes in the security alarms, door entry and cctv public area at. The difference being the addressable asd detector is used on the sita200plus, duonet and quadnet systems. General description the twinflex multipoint asd is a plugin type smoke detector that utilises a photo electric sensing chamber to make a measurement corresponding to smoke density. The panel also monitors each zone for detector head removal, device fault, end of. The rafiki twinflex multipoint detector with sounder is a detector unit that incorporates a builtin sounder.
This device is compatible with the twinflex 2wire fire alarm control panel and comprises a 2wire zonepowered mcp. This means that the detectors, call points, sounders and beacons can all be installed on the same radial zone circuit reducing the need to install seperate detection and sounder circuits. In this video i show a demo on testing a fike twinflex pro manual call point on a fike twinflex pro fire alarm panel. This is selectable by simply adjusting the switches on the reverse of the detector. The panel also monitors each zone for detector head removal, device fault, end of line fault and open or short circuit fault. The device also incorporates a thermistor sensing circuit to allow for accurate heat. The twinflex multipoint is an advanced detector that incorporates multicriteria detector, with advanced microprocessor control with 7 modes of detection that are controlled via a set of dil switches inbside the head. This means that separate smoke and heat detectors dont need to be ordered. Twinflex manual call points can be run on the same pair of wires as detectors.
Welcome to the sd fire alarms fike twinflex pro panel description part 1 video. Fike twinflexpro2 4 zone boxed kit approved 6040004. Rafiki twinflex fire twinflex two wire fire alarm system. The devices communicate with the control panel using the twinflex data protocol. Fike twinflex 2 zone fire alarm kit, fire protection. Instructions and manuals are best downloaded from our individual product pages via the menu bar above. For more information on the rafiki twinflex two wire fire alarm system call us now on 01200 428 410. However, for your convenience, the main instructions for each of ctecs product ranges typically our control panel manuals can be downloaded via the menus below. Twinflex is the name of the range of control panels and associated devices which together form the fire alarm system installed in the premises, and is derived from the method of wiring whereby trigger devices detectors and call points are connected to the same pair of wires, unlike the majority of. This kit includes the twinflex multipoint detectors which can be used as either a smoke or heat detector.
The creators of the panel fike utilised a conventional type cabling format when creating this panel. Please note that all fike components are only compatible with fike panels. Fike twinflex pro repeater panel discount fire supplies. Making it a simple, innovative and cost effective fire alarm system. This is the fike 2040001 twinflex multipoint asd detector complete with detector and sounder with base. View and download fike twinflex multipoint 2020003 installation and maintenance instructions online. Twinflex fire detection product range vista fire products. Fike twinflex manual call point with optional cover. Repeater panel engineering and commissioning manual.
Twinflexpro 2wire fire detection and alarm system and covers. Fike twinflex pro 2, 4 or 8 zone fire alarm kit kit contains a 2 zone twinflex pro panel, 7 twinflex multipoint detectors with sounder, 2 twinflex manual call points and a head removal tool ideal starting point for any twinflex installation. This device may be installed on the same zone as the twinflex multipoint detector sounder and other associated twinflex devices. The detector must be installed in compliance with the control panel installation manual. Twinflex multipoint detector the twinflex multipoint detector is a single device providing all the features of normal conventional smoke and heat detectors in a single unit, which can be configured to operate in one of seven modes to suit the environment in which it is located. The fike twinflex manual call point is connected to the 2wire zone circuit and provides the means to manually activate the fire alarm system. Twinflex v3 control panel engineering and commissioning instructions 5 introduction this manual is intended as a guide to the engineering and commissioning principles of the twinflex 2wire fire detection and alarm system, and covers the system hardware information only.
The twinflex pro system is an extremely intelligent 2wire system. The twinflex weatherproof manual call point mcp allows for user activation of the fire alarm system. It can also perform system controls over the network i. This device is compatible with the range of twinflex fire alarm control panels and. Fike twinflex fire alarms fire alarms sd fire alarms. Jun 09, 2009 twinflex manual call points can be run on the same pair of wires as detectors. Fike twinflex manual call point a 2wire manual call point, part of the fike twinflex family of products. The twinflex pro panel is able to recognise and separately identify between smoke detector, heat detector this feature will only be available with the future asd type of detectors, not the existing multipoint and a manual call point alarm. This device is compatible with the range of twinflex fire alarm control panels and comprises a 2wire zonepowered manual call point mcp.